Demineralised water of uninterrupted, traceable quality for analysis, instrument feed and precision rinsing, from reverse osmosis, EDI and mixed bed lines.

In the laboratory, water is used to prepare solutions and reagents, to rinse glassware, and to feed analytical instruments, autoclaves and climatic chambers. In electronics, optics and precision metal part manufacturing, the final rinse water touches the surface of the product. In both areas, ions, organic matter, particles and bacteria in the water either change the result of an analysis or leave residues on a surface. The target purity class is set by what the method or the process requires.

On these lines continuity is as decisive as capacity: quality must not drop when the polishing stage reaches exhaustion or is taken out for regeneration. Pure water can also deteriorate in the tank and pipework; the water absorbs carbon dioxide from the air and, where it stands still, becomes open to bacterial growth. The arrangement therefore does not end with production; it is handled together with storage, the distribution loop and continuous conductivity monitoring. Work that begins with a raw water analysis and site inspection continues with periodic inspections.

Where water is used

The decisive quality

  • Analysis and reagent preparation

    In preparing solutions, dilutions and blanks, the water is part of the analysis. Ionic purity is monitored by conductivity; in laboratories running trace element, organic or microbiological analyses, total organic carbon and bacterial load also become decisive.

  • Instrument feed water

    Autoclaves, glassware washers, humidifiers, climatic chambers and analytical instruments need water of the quality their manufacturer specifies. Hardness and dissolved salts leave deposits on heaters and nozzles, cause instrument failures and shorten maintenance intervals.

  • Precision part rinsing

    In the final rinse of electronic boards, optical components and precision metal parts, ions left on the surface create drying spots, corrosion or electrical leakage paths. Conductivity and particles are decisive at this step; the rinse water must reach the point of use at the same quality.

  • Storage and distribution

    At the many points of use fed from a central system, quality has to be preserved as it was produced. Contact with air in the tank raises conductivity, and dead legs in the pipework encourage bacterial growth. What is decisive is the conductivity and microbiological quality at the point of use.

Work out your line in a few steps

The solution finder opens with this sector selected; choose your water source and goal and it shows the treatment stages that fit.

Try the solution finder →

Frequently asked questions

How do you choose a pure water system for a laboratory?

First, the water class required by the methods and instruments in use and the daily consumption pattern are established. Then, based on the raw water analysis, pretreatment and a reverse osmosis main stage are designed, followed by an EDI or mixed bed polishing stage. If high purity is needed at only a few points, keeping the central system one class lower and adding a polishing unit at those points is often more economical.

What is the difference between pure, deionised and demineralised water?

In everyday use these terms are often used interchangeably. Deionised and demineralised water describe water from which the ions have been removed by ion exchange resins or EDI; reverse osmosis water is water from which most of the dissolved salts have been separated by a membrane. Pure water is a general expression. What matters for ordering and design is not the name but the measurable quality: conductivity, total organic carbon and, where needed, microbiological limits.

Should a pure water system use EDI or a mixed bed?

EDI polishes reverse osmosis permeate continuously using electricity; there are no regeneration chemicals and no regeneration downtime, but it is sensitive to feed water quality. A mixed bed reaches high purity and is simple to set up, but quality drops as the resin nears exhaustion, and regeneration or resin replacement is then needed. On lines where continuity comes first, EDI or redundant mixed bed columns are preferred; the decision depends on consumption, target quality and chemical handling.

Send us your raw water analysis and the flow rate you need

Let us size the system together; we will survey the site in person if needed.